Personal tools
You are here: Home Publications Modeling and Instrumentation for Fault Detection and Isolation of a Cooling System
 
Document Actions

Modeling and Instrumentation for Fault Detection and Isolation of a Cooling System

by Eric-Jan Manders last modified 2005-12-04 14:36

Abstract:

Functional redundancy techniques for fault detection and isolation (FDI) in dynamic systems requires close interaction between system instrumentation, modeling and analysis. Effective FDI requires detailed and accurate models to track and analyze system behavior, including transient phenomena that result from faults. It also requires appropriate instrumentation technology to provide the measurements to captur e and analyze system behavior. Models and measurements must be matched careful ly to provide sufficient observability and effective analysis. In this paper we demonstrate the development of FDI systems for complex applications by presenting an overview of the modeling and instrumentation of an automobile combustion engine cooling system. We have developed a qualitative parameter estimation methodology for FDI. A system model is represented as a graph that captures the dynamic behavior of the system. To demonstrate the applicability a small leak is artificially introduced in the cooling system and accurately detected and isolated.

Download: FeenstraEtal2000_SECON.pdf


Copyright 2000 IEEE. Published in the Proceedings of the SouthEast Conference, Nashville, TN USA. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works, must be obtained from the IEEE. Contact: Manager, Copyrights and Permissions / IEEE Service Center / 445 Hoes Lane / P.O. Box 1331 / Piscataway, NJ 08855-1331, USA. Telephone: + Intl. 908-562-3966.


Powered by Plone, the Open Source Content Management System